Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Heart Assoc ; 11(9): e021490, 2022 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-35502771

RESUMO

Background The FiGARO (FFR versus iFR in Assessment of Hemodynamic Lesion Significance, and an Explanation of Their Discrepancies) trial is a prospective registry searching for predictors of fractional flow reserve/instantaneous wave-free ratio (FFR/iFR) discrepancy. Methods and Results FFR/iFR were analyzed using a Verrata wire, and coronary flow reserve was analyzed using a Combomap machine (both Philips-Volcano). The risk polymorphisms for endothelial nitric oxide synthase and for heme oxygenase-1 were analyzed. In total, 1884 FFR/iFR measurements from 1564 patients were included. The FFR/iFR discrepancy occurred in 393 measurements (20.9%): FFRp (positive)/iFRn (negative) type (264 lesions, 14.0%) and FFRn/iFRp (129 lesions, 6.8%) type. Coronary flow reserve was measured in 343 lesions, correlating better with iFR (R=0.56, P<0.0001) than FFR (R=0.36, P<0.0001). The coronary flow reserve value in FFRp/iFRn lesions (2.24±0.7) was significantly higher compared with both FFRp/iFRp (1.39±0.36), and FFRn/iFRn lesions (1.8±0.64, P<0.0001). Multivariable logistic regression analysis confirmed (1) sex, age, and lesion location in the right coronary artery as predictors for FFRp/iFRn discrepancy; and (2) hemoglobin level, smoking, and renal insufficiency as predictors for FFRn/iFRp discrepancy. The FFRn/iFRp type of discrepancy was significantly more frequent in patients with both risk types of polymorphisms (endothelial nitric oxide synthaser+heme oxygenase-1r): 8 patients (24.2%) compared with FFRp/iFRn type of discrepancy: 2 patients (5.9%), P=0.03. Conclusions Predictors for FFRp/iFRn discrepancy were sex, age, and location in the right coronary artery. Predictors for FFRn/iFRp were hemoglobin level, smoking, and renal insufficiency. The risk type of polymorphism in endothelial nitric oxide synthase and heme oxygenase-1 genes was more frequently found in patients with FFRn/iFRp type of discrepancy. Registration URL: https://clinicaltrials.gov; Unique identifier: NCT03033810.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Insuficiência Renal , Angiografia Coronária/métodos , Feminino , Heme Oxigenase-1/genética , Hemodinâmica , Hemoglobinas , Humanos , Masculino , Óxido Nítrico Sintase Tipo III
2.
Artigo em Inglês | MEDLINE | ID: mdl-30215436

RESUMO

BACKGROUND: Ankle brachial index (ABI) is the principal screening method for peripheral arterial disease (PAD). In this study, we compare various types of Doppler-derived and oscillometric ABIs with results obtained through duplex ultrasonography. METHODS: 62 patients were enrolled in the study. For each limb, blood pressures for both ankle arteries and the arm were measured using Doppler and an automated oscillometric device. Duplex ultrasound was performed for all limbs and occlusions >50% were considered PAD-positive. ABI was calculated using both higher (HABP) and lower (LABP) arterial blood pressure on the individual limbs and the ability to predict duplex-detected stenoses was evaluated. RESULTS: LABP calculation provided results superior to the guideline-recommended HABP. Considering patients with ABI >1.4 or measurement failure as PAD-positive further enhanced the test parameters. The higher ABI cut-off of 1.0 resulted in somewhat better sensitivities (max 92%) and negative predictive values (max 87%) at the expense of a substantial increase in the number of false positives. Oscillometric method yielded poor sensitivities but very good specificities (max 94%) and positive predictive values (max 90%). CONCLUSIONS: Doppler-based LABP provides better results than the guideline-recommended HABP in diabetic patients, nevertheless even this method is not perfect. Increasing the cut-off value to 1.0 in these patients does not bring a substantial improvement of the test performance. Patients with high ABI should be automatically considered PAD-positive and referred for further investigation using imaging techniques.


Assuntos
Índice Tornozelo-Braço/métodos , Angiopatias Diabéticas/diagnóstico , Doença Arterial Periférica/diagnóstico , Idoso , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/fisiopatologia , Pressão Sanguínea/fisiologia , Angiopatias Diabéticas/fisiopatologia , Feminino , Humanos , Masculino , Doença Arterial Periférica/fisiopatologia , Sensibilidade e Especificidade , Ultrassonografia Doppler/métodos
3.
Artigo em Inglês | MEDLINE | ID: mdl-29235577

RESUMO

Out-of-hospital cardiac arrest (OHCA) is a leading cause of death in developed industrial countries. The global worldwide average of OHCA incidence in adults is 95.9/100,000/year. European incidences vary according to source from 16 to 119/100,000/year. The aim of this study was to provide an overview of current information on OHCA. The incidences in various populations are discussed, along with the factors affecting the prognosis and outcome of these patients. The etiology and pathophysiological mechanisms are also described, especially in relation to the most common causes - acute and chronic forms of coronary artery disease and cardiomyopathies. Measures that could improve survival rates are discussed, with emphasis on the role of the general public and deployment of automatic external defibrillators.


Assuntos
Parada Cardíaca Extra-Hospitalar/epidemiologia , Parada Cardíaca Extra-Hospitalar/fisiopatologia , Desfibriladores , Educação em Saúde , Humanos , Incidência , Parada Cardíaca Extra-Hospitalar/etiologia , Parada Cardíaca Extra-Hospitalar/terapia , Prognóstico , Taxa de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...